1. Technology
The 67SB Blast Probe is designed as a reference microphone for impulse measurements according to the ANSI S12.42 standard. The 67SB can measure impulse signals with an A-duration of 0.5 ms ≤ impulse ≤ 2.0 ms, and it has a working range of 10 Hz – 20 kHz. The 1/8” reference microphone inside the 67SB is ideally suited for capturing impulsive signals with a very fine time resolution. This microphone has an upper limit of 174 dB in the dynamic range.
The 67SB is equipped with a 1/8" reference microphone which is designed to capture impulsive noise with a very short duration. The 67SB is provided with a 1/4" threaded hole for monting the 67SB directly on a tripod e.g. AL0006.
The design and concept of the 67SB, and the microphone and preamplifier, comply with the following standards:
• ANSI S12.42 – “Methods for the Measurement of Insertion Loss of Hearing Protection Devices in Continuous or Impulsive Noise Using Microphone-in-Real Ear or Acoustic Test Fixture Procedures”
• IEC Standard 61094-1 – “Specifications for Laboratory Standard Microphones”
The 67SB has a length of 410 mm.
2. Specifications
Polarization/Connection
|
200 V / Traditional
|
Frequency range (±2 dB)
|
10Hz to 20kHz |
Dynamic range (mic. thermal noise - upper limit)
|
52 dB(A) - 174 dB
|
Microphone venting
|
Rear venting
|
Output Impedance
|
75 Ohm
|
Operating temperature
|
-30 to 70 °C
|
Storage temperature
|
-40 to 85 °C |
Static pressure coefficient @250 Hz
|
-0.01 dB/kPa at 25°C
|
Humidity range non condensing
|
0 tới 95 % RH
|
Humidity coefficient @250 Hz
|
-0.1 dB/% RH
|
Influence of axial vibration @1 m/s²
|
59 dB re 20 µPa
|
Connector type
|
7-pin LEMO (FGG.1B,307)
|
CE/RoHS compliant/WEEE registered
|
Yes/Yes/Yes
|
Weight
|
650 g
|